A novel ultrasound-guided electrosurgical loop device for intra-operative excision of breast lesions; an improvement in surgical technique

  • Richard E. Fine, M.D.

      Affiliations

    • Advanced Breast Care, Marietta, GA, USA
    • Corresponding Author InformationCorresponding author: Tel.: 770-422-1988; fax: 770-874-0226
  • ,
  • Michael A. Schwalke, M.D.

      Affiliations

    • Shreveport Breast Center, Shreveport, LA, USA
  • ,
  • James V. Pellicane, M.D.

      Affiliations

    • Virginia Breast Center, Midlothian, VA, USA
  • ,
  • Deanna J. Attai, M.D., F.A.C.S.

      Affiliations

    • Center for Breast Care, Glendale, CA, USA

Received 3 October 2008; received in revised form 6 January 2009

Abstract 

Background

The rate of involved margins after the excision of breast lesions using standard surgical techniques has historically ranged from approximately 20% to 45%. The localization and excision of breast lesions using intraoperative ultrasound has provided significant improvement. The authors report their collective experience with a novel technique utilizing the Phantom flexible loop electrosurgical device under ultrasound guidance for the intraoperative excision of breast lesions.

Methods

Seventy-nine breast lesions were excised using the Phantom device with intraoperative ultrasound. Rate of reexcision, excised specimen size, and size of the lumpectomy incision were reviewed.

Results

Fifty-nine of 79 lesions were malignant. Fifty-one (86.4%) had noninvolved final margins; 8 (13.6%) involved margins. The average specimen size was 21.3 cm3, compared with a range of 60 to 100 cm3 in the literature.

Conclusions

These results demonstrate improved efficiency, a decrease in the volume of excision, smaller incision size, and very low need for reoperation secondary to involved margins using the Phantom device for real-time, ultrasound-guided lumpectomy.

Keywords: Ultrasound, Lumpectomy, Breast-conserving surgery, Phantom flexible loop, Electrosurgical device, Margins, Biopsy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The authors disclose a proprietary interest in Rubicor Medical, Inc (Redwood City, CA), the manufacturer of the device used in this study.

PII: S0002-9610(09)00231-1

doi:10.1016/j.amjsurg.2009.01.026

The American Journal of Surgery
Volume 198, Issue 2 , Pages 283-286, August 2009